홈페이지> 블로그> Aerial Bundle Cable ABC Cable Overhead Cable

Aerial Bundle Cable ABC Cable Overhead Cable

April 09, 2024
Origin: Henan, China (Mainland)
Origin: Henan, China (Mainland)
Product Description
 

Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE / PE / PVC / LDPE insulation, Aluminum Conductor

Product Description

1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.

 Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474


Item#

Phase Conductor
 Size AWG

Phase
Conductor
Stranding

Phase Conductor
Insulation Thickness

Bare Neutral
Messenger
Size AWG

Bare
Neutral Strand

Bare Neutral messenger Breaking Strength

Weight Per 1000ft - XLP

Weight Per 1000ft - Poly

Rating - XLP

Rating-Poly

Pekingese

6

Solid

45 mls

6

7/w

563 Lbs

63.5 Lbs

61.7 Lbs

70 Amps

70 Amps

Collie

6

7/w

45 mls

6

7/w

563 Lbs

66.8 Lbs

63.1 Lbs

70 Amps

70 Amps

Dachshund

4

Solid

45 mls

4

7/w

881 Lbs

95.5 Lbs

93.4 Lbs

90 Amps

90 Amps

Spaniel

4

7/w

45 mls

4

7/w

881 Lbs

100.5 Lbs

95.4 Lbs

90 Amps

90 Amps

Doberman

2

7/w

45 mls

2

7/w

1350 Lbs

152.7 Lbs

145.7 Lbs

120 Amps

120 Amps

Malemute

1/0

19/w

60 mls

1/0

7/w

1990 Lbs

242.6 Lbs

234.2 Lbs

160 Amps

160 Amps


Product Description
 

Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE / PE / PVC / LDPE insulation, Aluminum Conductor

Product Description

1. Application of Service Drop Cable:
Service Drop Cable (ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop
The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.
3. Detailed Introduction of Service Drop Cable
3.1 Duplex Service Drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower ATA conductor temperature of 750C maximum.
Construction
Concentric stranded or compressed 1350-H19 conductor, polyethylene or cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.2 Triplex Service Drop
Applications
To supply power from the utility`s lines to the consumer`s weather head. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers are concentrically stranded 6210 AAAC, AAC or ACSR.

 Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474


Item#

Phase Conductor
 Size AWG

Phase
Conductor
Stranding

Phase Conductor
Insulation Thickness

Bare Neutral
Messenger
Size AWG

Bare
Neutral Strand

Bare Neutral messenger Breaking Strength

Weight Per 1000ft - XLP

Weight Per 1000ft - Poly

Rating - XLP

Rating-Poly

Pekingese

6

Solid

45 mls

6

7/w

563 Lbs

63.5 Lbs

61.7 Lbs

70 Amps

70 Amps

Collie

6

7/w

45 mls

6

7/w

563 Lbs

66.8 Lbs

63.1 Lbs

70 Amps

70 Amps

Dachshund

4

Solid

45 mls

4

7/w

881 Lbs

95.5 Lbs

93.4 Lbs

90 Amps

90 Amps

Spaniel

4

7/w

45 mls

4

7/w

881 Lbs

100.5 Lbs

95.4 Lbs

90 Amps

90 Amps

Doberman

2

7/w

45 mls

2

7/w

1350 Lbs

152.7 Lbs

145.7 Lbs

120 Amps

120 Amps

Malemute

1/0

19/w

60 mls

1/0

7/w

1990 Lbs

242.6 Lbs

234.2 Lbs

160 Amps

160 Amps


문의하기

Author:

Mr. Annry-wang

이메일:

wym@oikwan.com.cn

Phone/WhatsApp:

8613713335011

인기 상품
You may also like
Related Categories

이 업체에게 이메일로 보내기

제목:
이메일:
메시지:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

송신